Modular Vac-Rupter Interrupter

The Joslyn Modular Vac-RupterÒ Interrupter (MVI) is installed on a disconnect switch to provide load switching, line dropping or parallel switching capability through 230kV capability. The extremely high rate of dielectric recovery of vacuum interrupters enables restrike-free switching of loads of any power factor.

Applications include high voltage transmission line switching, capacitor bank switching, shunt reactor bank switching, and cable switching. Switches equipped with MVIs can provide a high degree of pole-to-pole synchronization.

MVIs are supplied complete with all mounting hardware for installation on most vertical break disconnect switches of any manufacturer. They re often supplied with Joslyn RF-2 vertical break switches as complete load interrupter switch packages.

Click on photo for graphical representation
    
Maintenance-Free
  Long life of 5,000 operations, no oil or SF-6 gas.
Ease of Installation
  Lightweight modules complete with mounting hardware allow quick and easy installation.
Flexible Application
  Adaptable to most vertical or horizontal mounting and is applicable to loads of any power factor .
Proven Performance
  Installations of more than 35 years demonstrate the reliability and proven performance of the interrupter.
Air Switch Ratings Unaffected
  The continuous, momentary, and impulse ratings of the switch are unaffected since the MVI is in the power circuit only for a few seconds.
     
            
Nominal
System
Voltage
(kV)
Maximum Interrupting Current (RMS Amperes) Modules
Required
Per
Phase*
Switching Application
70% P.F.
Load
Line Charging
or
3 Phase Cable
Capacitor Bank
Grounded
Neutral
Ungrounded
Neutral
14.4 2000
2000
600
600
800
1000
140
800
1
2
23 2000
2000
140
600
800
1000

600
1
2
34.5 2000
2000
600
600
700
700

600
2
3
46 2000
2000
2000
450
600
600
700
800
1000

140
600
2
3
4
69 2000
2000
2000
2000
450
600
600
600
600
600
600
600


450
600
3
4
5
6
115 2000
2000
2000
450
600
600
600
600
600
Consult
Factory
5
6
7
138 2000
2000
450
600
600
600
6
7
161 1200
2000
110
450
450
600
6
7
230 2000 110 450 8
Magnetizing current ratings or grounded air core reactor ratings are the same as grounded neutral capacitor ratings.
* Reduce number of modules with the Voltage Limiter Attachment
    
Ordering Information
1 Specify air switch manufacturer
2 Supply switch model number
3 Specify voltage and current rating
4 Indicate size of insulator bolt circle
5 Describe blade movement including rotation as viewed from hinge end
6 Specify application, system voltage and grounding
  