      Joslyn Hi-Voltage manufactures power transmission and distribution equipment for electric utilities - reclosers
     
Powerflex Two and Three Step Capacitor Switching Controllers

Powerflex Two and Three Step Capacitor Switching Controllers

The Fisher Pierce Powerflex Two and Three Step Capacitor Switching Controllers offer the most flexible and efficient method of capacitor switching. The controllers are intended for use with multiple capacitor racks found in substation applications.

The controls can be purchased in either 2 or 3 step configurations, measuring Var, Voltage, or Line Current. The control operates starting with the first step (module) and activates consecutively after a fixed time delay. The sequence is reversed when opening capacitors.

            
Rugged Enclosures
  Weatherproof foam or welded aluminum enclosures
Plug-In Modules
  Allows for user configuration
Surge Protection
  Three stages
Adjustment Knobs
  High torque, vibration-resistant adjustment knobs
I/O Test Jacks
  Accessible on main panel
         
Specifications
                             
Ordering Information 
  Follow the model number examples as shown, then select from the tables numbered 1 through 8
 

Multi-step controllers are available with fixed time delay only.
Sixty and 20 seconds standard, other delays on request.


MODEL NUMBER ORDERING GUIDE

Two Step Module Number System
   Example: Voltage
TABLE 1 3 2 3 4 5 6 7 8
  2406 D 35 D W J 6 6 B

Three Step Module Number System
   Example: Voltage
TABLE 1 3 2 3 2 3 4 5 6 7 8
  2406 D 35 D 35 D W J 6 6 B
  Table 1. First Step
CODE TYPE
2406 Voltage
4604* VAr, use Fisher Pierce Series 1301 standard line post sensor, 3Ø, 4W, Wye system.
4608 VAr, use 5A C.T. 3p, 4W, Wye system.
4609 VAr, use 5A C.T. 3p, 4W, Delta system.
4620* VAr, use Fisher Pierce Series 1301 high accuracy line post sensor, 3Ø, 4W, Wye system
4844 Line current, use Fisher Pierce Series 1301 standard or high accuracy line post sensor.
4846 Line current, use 5A C.T.
*Available for multi-step controllers only

Table 2. Second and/or Third Step
CODE TYPE
35 Voltage
36 Line current, use with 4844
37 Line current, use with 4846
38* VAr, use with 4604
39 VAr, use with 4608
40 VAr, use with 4609
64* VAr, use with 4620
*Available for multi-step controllers only

Table 3. Time Delay
CODE TIME
D 60 seconds (standard)
B 20 seconds (standard)
Spec. No. Non standard time delay, consult factory

Table 4. Mounting Configuration
CODE DESCRIPTION
W Flat wall bracket
B Wrap-around pole bracket

Table 5. External Wiring Connections
CODE DESCRIPTION
J 12 terminal wiring strip

Table 6. Enclosure
CODE DESCRIPTION
3 Aluminum, 8"w x 7"d x 18"h
6 Structural foam, 9.25w" x 8.5d" x 15.25h"
2 None

Table 7. Operating Information
CODE DESCRIPTION
3 240V, 50Hz, 5A fuse
5 120V, 50 Hz, 5A fuse
6 120V, 60 Hz, 5A fuse
8 120V, 60 Hz, 10A fuse

Table 8. Model Generation
CODE DESCRIPTION
B Step Controller
   

Options and Accessories

Current Sensor
  

Joslyn Hi-Voltage Royce Thompson Fisher Pierce