Thomas & Betts
Sales Partner Login
      Joslyn Hi-Voltage manufactures power transmission and distribution equipment for electric utilities - reclosers
     
SmartLink

SmartLink Monitoring and Control Devices provide a cost effective, maintenance-free communication system for distribution automation. The system utilizes the existing nationwide Cellular and Public Switched Telephone Networks to provide field information in seconds. All units have two-way communication with optional monitoring and control features.

SmartLink targets distribution automation applications requiring constant monitoring for alarm, maintenance, status reporting and switch control. SmartLink Systems provide solutions for new distribution users, expansion of system coverage, and new monitoring applications.

Click on photo for graphical representation

 
          


Feeder Automation Made Simple
Your Lights Are Out!
  

Fault Monitoring
Sectionalizing Switch Monitoring
Motor Operated Switch Control
Capacitor Switch Control
"Pole-Top" Substation
Alarm Reporting
Equipment Maintenance Reporting
Load Monitoring
Transformer Monitoring  
                   
Specifications
    
Ordering Information
   To order a Series 2700 Control, specify a code number or letter for each of the following: (1) Basic Model Number, (2) Cell Modem Type, (3) Line Voltage, (4) Enclosure Type, (5) Meter Socket Wiring, (6) Function, (7) Battery Backup, (8) External MS Connector Input/Output, (9) Additional Options (See example of 2721L-SJ-FV-B-NN-NNN-X below). Not all combinations are available, consult factory.
1 Basic Model Number
2 Cell Modem Type
3 Line Voltage
4 Enclosure Type
5 Meter Socket Wiring
6 Function
7 Battery Backup
8 External MS Connector Input/Output
9 Additional Options
    

   
Code (1) Basic Model Number
27 Base Model
   (2) Cell Modem Type
2 Cell Modem
   (3) Line Voltage
1 120 Vac 60 Hz
5 Solar Powered
   (4) Enclosure Type
A Aluminum
L Lexan
   (5) Meter Socket Wiring
FJ

Four Blade Lexan/Aluminum

BJ

Pole Mount Aluminum

WJ

Wall Mount Aluminum

SL

Six Blade Lexan/Aluminum

FM

Flush Mount/Lexan

SY

Six Blade Lexan/Aluminum

ST

Six Blade Lexan/Aluminum

RC*

Radio control cover assembly
*Consult factory for abailability

     (6) Function
SC

Switch Control with 2 dry isolated relay outputs

FN

Fault (FCI) Monitor

VN

Capacitor Control with either Radio as Primary Mode with Voltage Override or Voltage as Primary Mode with Radio Override (Sec. 8 NN only, Sec. 5 SY, ST N/A)

FR

Fault (FCI) monitor with 2 dry isolated control relay outputs (Sec. 5, FJ N/A, Sec. 8 SN N/A)

FH Fault Monitor with two 120 Vac NO switched contacts (Sec 5, FJ N/A, Sec 8, SN N/A)
*FS

Solar Fault monitor (Sec. 8, SN, NN only, Sec. 5 WJ, BJ only)
*Consult factory for availability

**NN

4400 Radio override door mounted module
**Order At2613-4400 pcb and an RS232 cable for door mounting

VM Voltage Monitoring (no switch or fault monitoring capability)
Select code N on section 7 code NN on section 8.
    (7) Battery Backup
B Required on fault monitor (FN, FR, FH) and solar models (FS) in section 6
N None
    (8) External MS Connector Input/Output
SW 3 Status in (wetted)/2 status in dry, (alum. enc. 10 pin MS conn.)
SP 5 Wetted status inputs (cust. wetted) (Alum. encl., 10 pin MS conn.)
SD Two status dry contact inputs (internally wetted) (alum. Encl., 5 pin MS conn.)
SN Four wetted status inputs (cust. wetted)(solar only)alum. encl., 8 pin MS conn.)
NN NONE
    (9) Additional Options
GNC Ground lug and capacitor neutral current
NNC Capacitor neutral current
GN3 Ground lug and 3 single phase capacitor cur.
NN3 3 single phase capacitor current
NNG Ground lug
NNN NONE
       
    Flat wall or Wrap-Around Pole Bracket Mounting and Terminal Strip
Section 5 Wiring
BJ
WJ
Terminal strip as shown below
  
Terminal Strip (Aluminum Enclosure Only)

Broken lines between terminals indicate removable jumper
       
Four Stab Meter Socket Mounting and Wiring
Section 5 1 2 3 4 5 6
FJ L NEUTRAL TR CL - -
   
Six Stab Meter Mounting and Wiring
Section 5 1 2 3 4 5 6
SL L NEUTRAL NSL NSL TR CL
SY TR NEUTRAL L TR CL CL
ST L NEUTRAL TR CL TR CL
        

 

View looking
into socket

   

Options and Accessories

Faulted Circuit Indicators
  

Joslyn Hi-Voltage Royce Thompson Fisher Pierce

Home | About Us | Products | Library | Contact Us | Chinese Site

Joslyn Hi-Voltage - 4000 E 116th Street, Cleveland, Ohio 44105 USA   Email: T&B Contact Information
Copyright © 2001 Joslyn Hi-Voltage. All rights reserved.
   
Royce Thompson