      Joslyn Hi-Voltage manufactures power transmission and distribution equipment for electric utilities - reclosers
     
VBU Faultmaster Interrupter

VBU Faultmaster Interrupter

The VBU switching system is ideal for capacitor switching and is suitable for all loads. The VBU utilizes a modular design concept which connects vacuum interrupter modules electrically in series and mechanically in parallel. The flexibility of modular design makes changing the voltage rating as simple as adding or subtracting vacuum contact modules.

The VBU switching system is completely sealed against the environment. They are immune to ice and to the effects of contamination. No heaters are required. The VBU is designed to withstand system voltage continuously in the open position.

The VBU switch system contains vacuum interrupters that are surrounded by Joslyte™, the 35-year field proven solid dielectric insulation. VBU switches offer high reliability for applications of system voltages from 69 to 230kV with continuous current capability from 600 amperes.

Click on photo for graphical representation


Maintenance-Free Long Life
  Inspection only every 5 years or 10,000 operations.
Completely Sealed Construction
  Environmental protection system eliminates effects of ice and contamination.
Easy Installation
  Lightweight construction of units allow the factory assembled unit to be installed easily.
Safe, Oil-Free
  VBU switches are free of explosive and combustible materials and are safe even when exposed to fault currents that exceed the equipment rating.
Low Cost
  VBU switches are less expensive than circuit breakers to purchase and install and are essentially maintenance-free.
                
                
Rated Maximum Voltage kV L-G BIL kV Interrupter Modules
per Phase
A B Wt.
per
Phase Lbs.
Primary Application*
72 350 4 8' 7 1/4" 30" 710 T G U
121 550 5 11' 1 1/4" 48" 860 T G
121 550 7 13' 1 1/4" 48" 940 U
145 750 6 13' 1 1/4" 60" 950 T
145 750 7 14' 1 1/4" 60" 990 G
145 750 8 15' 1 1/4" 60" 1030 U
169 750 7 14' 1 1/4" 60" 990 T
169 750 8 15' 1 1/4" 60" 1030 G
169 750 9 16' 1 1/4" 60" 1070 U
242 900 9 17' 7 1/4" 78" 1180 T G
*T - Transformer Switching & Fault Protection - Grounded or Ungrounded
G - Shunt Capacitor or Reactor Switching - Solidly Grounded Source & Load
U - Shunt Capacitor or Reactor Switching - Ungrounded Source & Load

Ordering Information
 1 Select intended application:
Capacitor switching, reactor switching, or filter bank switching
2 Specify Voltage Rating: 69 kV, 121 kV, 145 kV, 242 kV
  3   Specify 120 V AC, 48 V DC, 125 V DC, or 250 V DC Control Voltage
  4   Select Options and Accessories
  
Options and Accessories    
Zero Voltage Closing Control Junction Box
Capacitor Controls Time Delay Relay
Undervoltage Trip Control Heater for Control Enclosures
Low Energy Solenoid Control Electrical Operations Counter
Current Limiting Reactors Upright Stands and Pole Mounting Frames
Overcurrent Relay Packages Special Controls
  

Joslyn Hi-Voltage Royce Thompson Fisher Pierce

Home | About Us | Products | Library | Contact Us

Joslyn Hi-Voltage - 4000 E 116th Street, Cleveland, Ohio 44105 USA   Email: jhv_info@tnb.com
Copyright © 2001 Joslyn Hi-Voltage. All rights reserved.
   
Royce Thompson