Thomas & Betts
Press Room
Sales Partner Login
      Joslyn Hi-Voltage manufactures power transmission and distribution equipment for electric utilities - reclosers
     
Voltage Limiter

The Joslyn Voltage Limiter used in parallel with the UVI or MVI attachments extends the interrupting capability. Interrupter switches equipped with voltage limiters have fewer vacuum modules for a given rated voltage than similar switches without limiters, because the transient recovery voltage is reduced during switching.

  
Increased Personnel Safety
  Reduces switch misoperation because the device provides multiple functions.
Increased Efficiency
  No sequential switching requirements.
Reduces Cost
  Fewer number of vacuum modules, simplified installation.
     

The addition of the Voltage Limiter to the UVI allows for applications of transmission line charging current and transformer magnetizing current interruption at voltages up to 72.5kV and provides 2000 amperes of loop splitting or parallel switching capability.

The combination enables a single switch to either be opened to split a loop or drop charging current, the two operations required to isolate a section of a transmission line for maintenance. Sequential switching operations or temporary outages are thereby eliminated resulting in a safer, more efficient, and more reliable system.


The addition of the Voltage Limiter to the MVI used for parallel switching, line or cable dropping allows the number of vacuum modules to be reduced. The resulting product is smaller for easy installation and less costly as compared to full load break interrupter attachments.

The system provides line dropping and cable switching through 230kV, as well as 2000A of loop splitting or parallel switching.

  
    
Maximum System
Voltage
(Line-to-Line)
Line Charging
Current
Interrupting Rating
Parallel or Loop
Switching
Interrupter
Type
Voltage Limiter
Type
38kV 25A
50A (cable)
2000A
2000A
UVI
UVI
10ZJ
10ZJ 
48.3kV 20A
25A (cable)
2000A
2000A
 
UVI
UVI  
10ZJ
10ZJ 
72.5kV 15A
50A
50A (cable)
2000A
2000A
2000A
 
UVI
MVI (2)*
MVI (2)*
10ZJ
7ZJ
7ZJ
121kV 15A
50A (cable)
2000A
2000A
 
MVI (2)*
MVI (2)*
 
10ZJ
10ZJ
145kV 10A
20A
50A (cable)
2000A
2000A
2000A
 
MVI (2)*
MVI (3)*

MVI (3)*
10ZJ
7ZJ
7ZJ
169kV 25A
50A (cable)
2000A
2000A
 
MVI (3)*
MVI (3)* 
10ZJ
10ZJ
242kV 15A
100A
50A (cable)
2000A
2000A
2000A
 
MVI (4)*
MVI (5)*
MVI (5)*
10ZJ
10ZJ
10ZJ
* number of vacuum modules in series
  

Joslyn Hi-Voltage Royce Thompson Fisher Pierce

Home | About Us | Products | Library | Contact Us

Joslyn Hi-Voltage - 4000 E 116th Street, Cleveland, Ohio 44105 USA   Email: jhv_info@tnb.com
Copyright © 2001 Joslyn Hi-Voltage. All rights reserved.
   
Royce Thompson