      Joslyn Hi-Voltage manufactures power transmission and distribution equipment for electric utilities - reclosers
     
Automatic Sectionalizing Voltage-Time (V-T) Control

Automatic Sectionalizing - combining recloser and sectionalizer logic without current coordination problems.

Joslyn reclosing sectionalizers are unique in combining recloser and sectionalizer logic without current coordination problems.

Unlike other reclosers and sectionalizers, Joslyn reclosing sectionalizers do not require fault current detection or count the number of recloser shots prior to lockout. The control automatically opens the Joslyn vacuum switch during the "dead time" of the station or line recloser. The Joslyn switches then systematically close as voltage is restored to their source side until the faulted section is located causing automatic opening and lockout of the Joslyn switch that closed into the fault. This basic voltage time (V-T) logic does not require current coordination, thereby eliminating problems for short highly loaded distribution lines.

       
Recloser * Indicates feature is DIP switch selectable
Safety Feature *
  Maintenance safety feature automatically opens the switch with no reclose if voltage is lost while control is set in the manual position which prevents reclosing into personnel on the line.
"Selected Close" Feature*
  Allows selective closing to energize a distribution line segment from a selected source.
Proprietary "Immediate Second Close" Feature*
  Significantly reduces total system restoration time.
Voltage Time "(V-T) Close Inhibit" Feature*
  Automatically prevents closing if line is energized on both sides of a "V-T" switch, while it is in the open position.
Power On-Off Switches and Indication
Remote Indication Contacts
Settings Easily Visible
  Timer and option setting label to record all setting on inside of front door.
Control Check
  All controls are "burned in" for a minimum of 48 hours at 140 degrees Fahrenheit with full control power to detect components infant mortality.
Tested to Standard
  Control has been tested to pass the ANSI/IEEE C37.90.1, 1974 standard.
Manual Operation
  Open and close toggle switch.
No Batteries Required
Microprocessor Controlled
  On board ROM (EPROM) and RAM.
Open-Tie (O-T) Option*
"Source Side Lockout Logic" Timer*
  With customer settable source side lockout timer and (O-T) source side reset timer.
    
Reclosers Ordering Information
1 Specify version
 
Version 1 This control includes all three (3) option P.C. boards and the "OT" option.
Version 2 This control includes the "OT" option and has provisions for all three (3) plug in option P.C. boards. The Option P.C. boards must be ordered separately.
Version 3 This control includes all of the standard featured options including the "OT" option. This control version does not have provisions for the three (3) option P.C. boards.
Version 4 This control includes all of the standard featured options not including the "OT" option. Sockets are provided to add the "OT" option. This control does not have provisions for the three (3) option P.C. boards.
    
Options and Accessories
Three-Phase Voltage Sensing Option P.C. Board. (6 inputs maximum)
Remote Control Input Option P.C. Board
High Overcurrent with Voltage Loss Options P.C. Board. (includes 3 optional responses)
"OT" Option Relays. (For upgrading a version 4 to a version 3)
Terminal Box - mounted on Vacuum Switch for hard wiring between Switch and Control
Shielded Cable with Plug on both Cable ends and Cable Connector on the bottom of the Control Cabinet
Cable Connector on the bottom of the Control Cabinet and Plug with Cable for 120 VAC Power Source, 25 foot length standard
External Lamp (Amber) Lockout Indication
External Lamp (Red/Green) for Vacuum Switch (Closed/Open) Indication respectively
Simulator Control Box with Cable - Tester Box for Switch Simulation
Low Temperature Package for Operation to -50C
Control Cabinet Door Closing Toggle Clamps
Cable Connector on the bottom of the Control Cabinet and plugs with Cables for three (3) phase 120 VAC inputs. Specify length
Operations Counter in the Control. (Note that a mechanically actuated Operations Counter is supplied on the VBM Switch as standard)
Control Cabinet with Extra Space for a RTU, and/or RADIO
Control Cabinet with Battery Backup for Dead Line Switching
Joslyn Control with Power Supply and Battery Backup for Radio and RTU. Specify RTU and Radio
High Security Cable with Internal Connectors
    
For use with Joslyn Distribution Vacuum Switches
  