      Joslyn Hi-Voltage manufactures power transmission and distribution equipment for electric utilities - reclosers
     
Varmaster

Varmaster switching systems use VBM switches that are completely sealed breaker class devices utilizing vacuum as the interrupting dielectric. Varmaster switching systems use VBM switches that are completely sealed breaker class devices utilizing vacuum as the interrupting dielectric. VBM switches offer high reliability with little or no maintenance. Interruption is safe, arcless, and quiet. VBM interrupters are manufactured for application at system voltages from 15 to 69kV with continuous current capability from 200 amperes. Vacuum interrupters are connected electrically in series to provide the necessary recovery voltage characteristics for the specific application. Vacuum interrupters may also be connected electrically in parallel for high continuous or momentary current requirements.

VBM brochure

VBM Instructions
Click on photo for graphical representation
Now available with
Vacstat vacuum interrupter monitor vacuum interrupter monitor!
     
Varmaster switching systems
THREE PHASE
15kV/25kV¹ 400A
15kV/25kV¹ 600A
Varmaster switching systems
THREE PHASE
25kV 200A
25kV 300A
25kV 400A
Varmaster switching systems
THREE PHASE
38kV 300A
     
Varmaster switching systems
ONE POLE²
38kV 400A
38kV 600A
48.5kV 200A
(with longer insulators)
Varmaster switching systems
ONE POLE²
48.5kV 300A
48.5kV 400A
Varmaster switching systems
ONE POLE²
72.5kV 300A
     
1 Solid grounded system and capacitor banks only
2 Three poles required for a three phase installation
     
Maintenance-Free Long Life
  100,000 operations on AC and 15,000 operations on DC with solenoid operating mechanism.
Completely Sealed Construction
  Environmental protection system consisting of a breather chamber and dessicant prevents moisture and contamination from entering the switch.
Low Cost Installation
  Lightweight construction requiring no special foundations or supports allow the factory assembled unit to be bolted right into place.
High Speed Operation
  Stored energy operating mechanisms, that can be operated manually or electrically, move the contacts at a high speed unaffected by control voltage fluctuation or manual operating speed.
Choice of Operating Mechanisms
  Solenoid or motor operated.


VBM Switch
MAXIMUM VOLTAGE
Capacitor Switching and
Continuous Current1,2 (Amperes)
Fault Interrupting Current (Amperes)
Momentary Current (kA) (RMS Amperes, Asysmetric)
Two-Second Current (kA) (Amperes)
Four-Second Current (kA) (Amperes)
Impulse Withstand, Terminal to Terminal5/Line to Ground (1.2 x 50 Positive Wave)

Maximum 60-Cycle Withstand, Line to Ground (kV): One Minute Dry
Ten Seconds Wet

Maximum Peak Making Current (kA)

Maximum Peak Back-to-Back Inrush Current 6 (kA)

15.5kV/25kV3
400 600 600
3kA 4kA 8kA
20 20 20
12.5 12.5 12.5
9 9 9
110/
150
110/
150
110/
150
101
74
101
74
101
74
20 20 20
10 10 10
25kV
200 300 400
3kA 3kA 3kA
15 15 15
12.5 12.5 12.5
9 9 9
200/
150
200/
150
200/
150
101
74
101
74
101
74
15 15 15
8 8 8
38kV
300 400 600 600
3kA 3kA 4kA 8kA
15 20 20 20
12.5 12.5 12.5 12.5
9 9 9 9
200/
200
200/
200
200/
200
200/
200
138
119
138
119
138
119
138
119
15 20 20 20
8 10 10 10
48.5kV
2004 300 400
4kA 3kA 3kA
20 15 15
12.5 12.5 12.5
9 9 9
200/
250
250/
250
250/
250
178
176
178
176
178
176
20 15 15
10 8 8
72.5kV
300
3kA
15
12.5
9
280/
350
178
176
15
8
  Varmaster VBM Vacuum Capacitor Switch Specifications
   
  Ratings Table Reference
1 VBM Varmasters can switch loads of any power factor up to their continuous current rating. Include effects of voltage, harmonic currents and tolerance size of load in calculating continuous current.
2 VBM Varmasters are available with continuous current ratings through 3000 amperes. Consult factory regarding application of these switches.
3 Grounded systems only
4 In capacitor switching applications the 48.5kV, 600 ampere VBM may be used on solidly grounded systems and grounded capacitor banks with total current less than 200 amperes. For all other loads, this VBM rating is 600 amperes.
5 Interrupter portion of switch does not provide a visible open gap; therefore, it cannot be used to establish a safety clearance for personnel.
6 In back-to-back capacitor bank switching applications, it is recommended that inrush current be limited to the values shown for maximum maintenance-free performance. Current limiting reactors through 60 microhenries/phase are available from Joslyn Hi-Voltage. Refer to Joslyn bulletin T.D. 750-457

Operating Mechanism Options
 
Control
Voltage
Operating
Mechanism
Control Current
Per Switch Mechanism
Close
Time
4
Trip
Time
4
Auxilliary
Controls
AC 120V Motor5
Solenoid3
5 amps
60 amps7,8
3 sec
6 cycles
2 cycles
6 cycles
2"a"and 2"b"1
4"a"and 4"b"2
DC 48V Motor3
Solenoid3,8
3 amps
60 amps6
5 sec
6 cycles
2 cycles
6 cycles
2"a"and 2"b"1
4"a"and 4"b"2
125V Motor5
Solenoid3
4 amps
60 amps7,8
3 sec
6 cycles
2 cycles
6 cycles
2"a"and 2"b"1
4"a"and 4"b"2
250V Solenoid3,8 60 amps7,8 6 cycles 6 cycles 4"a"and 4"b"2
1 Two A and two B mechanically operated contacts are standard. Six A and six B contacts available as option. Contacts are rated at 10 amps 125 VDC or 115 VAC.
2 Four A and four B contacts from auxilliary relay. Eight A and eight B contacts available as option. Contacts are rated at 15 amps 120 VAC and 10 amps or 125 VDC.
3 For capacitor or reactor switching, a low energy controls available.
See Options and Accessories.
4 Close or Trip Times are measured from applying of close or trip signals. Vacuum contact travel time is six milliseconds. All VBM's have built-in anti-pump controls.
5 Motor operating mechanisms are designed for single mechanism switches only.
6 Current is 60 amperes peak for one, two or three mechanism switch systems.
7 Current is 120 amperes (or 34.5 kV 300A VBM)
8 Current for three mechanism switch systems is approximately 180 amperes peak for 3 cycles.

Ordering Information
1 Select a VBM switch from ratings table above.
2 Select operating mechanism and voltage.
3 Select Varmaster Teminal Pad Orientation (Standard A, B, or C)
4 Select standard options and accessories.
5 Specify intended application.

Options and Accessories    
Zero Voltage Closing Control Junction Box
Capacitor Controls Time Delay Relay
Under Voltage Trip Control Heater for Control Enclosures
Low Energy Solenoid Control Electrical Operations Counter
Current Limiting Reactors Upright Stands and Pole Mounting Frames
Overcurrent Relay Packages Special Controls
  

Joslyn Hi-Voltage Royce Thompson Fisher Pierce

Home | About Us | Products | Library | Contact Us | Chinese Site

Joslyn Hi-Voltage - 4000 E 116th Street, Cleveland, Ohio 44105 USA   Email: T&B Contact Information
Copyright © 2001 Joslyn Hi-Voltage. All rights reserved.
   
Royce Thompson