Now available with |
vacuum interrupter monitor! | |||
![]() THREE PHASE 15kV/25kV¹ 400A 15kV/25kV¹ 600A |
![]() THREE PHASE 25kV 200A 25kV 300A 25kV 400A |
![]() THREE PHASE 38kV 300A |
||||
![]() ONE POLE² 38kV 400A 38kV 600A 48.5kV 200A (with longer insulators) |
![]() ONE POLE² 48.5kV 300A 48.5kV 400A |
![]() ONE POLE² 72.5kV 300A |
||||
|
||||||
| Maintenance-Free Long Life | |
| 100,000 operations on AC and 15,000 operations on DC with solenoid operating mechanism. | |
| Completely Sealed Construction | |
| Environmental protection system consisting of a breather chamber and dessicant prevents moisture and contamination from entering the switch. | |
| Low Cost Installation | |
| Lightweight construction requiring no special foundations or supports allow the factory assembled unit to be bolted right into place. | |
| High Speed Operation | |
| Stored energy operating mechanisms, that can be operated manually or electrically, move the contacts at a high speed unaffected by control voltage fluctuation or manual operating speed. | |
| Choice of Operating Mechanisms | |
| Solenoid or motor operated. | |
| VBM Switch |
|
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Varmaster VBM Vacuum Capacitor Switch Specifications | ||
| Ratings Table Reference | ||
| 1 | VBM Varmasters can switch loads of any power factor up to their continuous current rating. Include effects of voltage, harmonic currents and tolerance size of load in calculating continuous current. | |
| 2 | VBM Varmasters are available with continuous current ratings through 3000 amperes. Consult factory regarding application of these switches. | |
| 3 | Grounded systems only | |
| 4 | In capacitor switching applications the 48.5kV, 600 ampere VBM may be used on solidly grounded systems and grounded capacitor banks with total current less than 200 amperes. For all other loads, this VBM rating is 600 amperes. | |
| 5 | Interrupter portion of switch does not provide a visible open gap; therefore, it cannot be used to establish a safety clearance for personnel. | |
| 6 | In back-to-back capacitor bank switching applications, it is recommended that inrush current be limited to the values shown for maximum maintenance-free performance. Current limiting reactors through 60 microhenries/phase are available from Joslyn Hi-Voltage. Refer to Joslyn bulletin T.D. 750-457 | |
| Operating Mechanism Options | ||||||
|
Control
Voltage |
Operating
Mechanism |
Control
Current
Per Switch Mechanism |
Close
Time4 |
Trip
Time4 |
Auxilliary
Controls |
|
| AC | 120V | Motor5 Solenoid3 |
5 amps 60 amps7,8 |
3 sec 6 cycles |
2 cycles 6 cycles |
2"a"and
2"b"1
4"a"and 4"b"2 |
| DC | 48V | Motor3 Solenoid3,8 |
3 amps 60 amps6 |
5 sec 6 cycles |
2 cycles 6 cycles |
2"a"and
2"b"1
4"a"and 4"b"2 |
| 125V | Motor5 Solenoid3 |
4 amps 60 amps7,8 |
3 sec 6 cycles |
2 cycles 6 cycles |
2"a"and
2"b"1
4"a"and 4"b"2 |
|
| 250V | Solenoid3,8 | 60 amps7,8 | 6 cycles | 6 cycles | 4"a"and 4"b"2 | |
| 1 | Two A and two B mechanically operated contacts are standard. Six A and six B contacts available as option. Contacts are rated at 10 amps 125 VDC or 115 VAC. | |
| 2 | Four A and four B contacts from auxilliary relay. Eight A and eight B contacts available as option. Contacts are rated at 15 amps 120 VAC and 10 amps or 125 VDC. | |
| 3 | For
capacitor or reactor switching, a low energy controls available. See Options and Accessories. |
|
| 4 | Close or Trip Times are measured from applying of close or trip signals. Vacuum contact travel time is six milliseconds. All VBM's have built-in anti-pump controls. | |
| 5 | Motor operating mechanisms are designed for single mechanism switches only. | |
| 6 | Current is 60 amperes peak for one, two or three mechanism switch systems. | |
| 7 | Current is 120 amperes (or 34.5 kV 300A VBM) | |
| 8 | Current for three mechanism switch systems is approximately 180 amperes peak for 3 cycles. | |
| Ordering Information | ||
| 1 | Select a VBM switch from ratings table above. | |
| 2 | Select operating mechanism and voltage. | |
| 3 | Select Varmaster Teminal Pad Orientation (Standard A, B, or C) | |
| 4 | Select standard options and accessories. | |
| 5 | Specify intended application. | |
| Options and Accessories | ||||
| Zero Voltage Closing Control | Junction Box | |||
| Capacitor Controls | Time Delay Relay | |||
| Under Voltage Trip Control | Heater for Control Enclosures | |||
| Low Energy Solenoid Control | Electrical Operations Counter | |||
| Current Limiting Reactors | Upright Stands and Pole Mounting Frames | |||
| Overcurrent Relay Packages | Special Controls | |||
|